Free Standing Lifting StationsSanicubic 2 VX
Ambient visual of the Sanicubic 2 VX S, single-phase, lifting station to be installed for grey/black water in the basement.

Sanicubic 2 VX

The Sanicubic 2 VX is ideal for residential buildings, commercial buildings, restaurants, schools, hotels, shopping centres. It is easy to install as it stands on the floor and does not need to be positioned below ground.
2 motors for more intensive use
Numerous inlets available
Standard equipment
Find out more

Product details

The Sanicubic 2 VX has vortex KXV6 technology enabling 50mm diameter evacuation. In addition, the two motors enable operation in all circumstances. Its 5 inlets make it possible to connect all the sanitary facilities required. It comes with remote control and alarm as standard. Lastly, it is available in single-phase and three-phase versions. It is the most complete and the most high-performance in the Sanicubic range. This floor-standing pumping station is made in France at the Brégy (60) SFA factory. It has thus received the Guarantee of French Origin.
Technical specification

Sanicubic 2 VX

  • Version
  • Version
  • Version
  • Version
  • Sanicubic 2 VX S
  • Version
  • Sanicubic 2 VX S Smart
  • Version
  • Sanicubic 2 VX T
  • Version
  • Sanicubic 2 VX T Smart

Materials

  • Shaft
  • Tank
  • Pump housing
  • Seal
  • Motor housing
  • Impeller
  • Shaft
  • Shaft
  • Tank
  • Tank
  • Pump housing
  • Pump housing
  • Seal
  • Seal
  • Motor housing
  • Motor housing
  • Impeller
  • Impeller
  • Shaft
  • 1.4021
  • Tank
  • PP GF
  • Pump housing
  • PA 12 GF
  • Seal
  • NBR
  • Motor housing
  • PA 12 GF
  • Impeller
  • PPO GF
  • Shaft
  • 1.4021
  • Tank
  • PP GF
  • Pump housing
  • PA 12 GF
  • Seal
  • NBR
  • Motor housing
  • PA 12 GF
  • Impeller
  • PPO GF
  • Shaft
  • 1.4021
  • Tank
  • PP GF
  • Pump housing
  • PA 12 GF
  • Seal
  • NBR
  • Motor housing
  • PA 12 GF
  • Impeller
  • PPA GF
  • Shaft
  • 1.4021
  • Tank
  • PP GF
  • Pump housing
  • PA 12 GF
  • Seal
  • NBR
  • Motor housing
  • PA 12 GF
  • Impeller
  • PPA GF

Electrical features

  • Number of motor(s)
  • Socket included
  • Voltage (V)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • IP rating
  • Electrical class
  • Motor insulation class
  • Current
  • Length of cable-control box (m)
  • Number of pumps
  • Type of control box
  • Length (m)
  • Section (mm²)
  • Type of cable
  • Number of motor(s)
  • Number of motor(s)
  • Socket included
  • Socket included
  • Voltage (V)
  • Voltage (V)
  • Frequency (Hz)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • Maximum current (A)
  • IP rating
  • IP rating
  • Electrical class
  • Electrical class
  • Motor insulation class
  • Motor insulation class
  • Current
  • Current
  • Length of cable-control box (m)
  • Length of cable-control box (m)
  • Number of pumps
  • Number of pumps
  • Type of control box
  • Type of control box
  • Length (m)
  • Length (m)
  • Section (mm²)
  • Section (mm²)
  • Type of cable
  • Type of cable
  • Number of motor(s)
  • Dual motor
  • Socket included
  • No
  • Voltage (V)
  • 220-240
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 2000
  • Power output P2 (W)
  • 1400
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 16
  • IP rating
  • IP68
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Current
  • Single-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Classic
  • Length (m)
  • 2,5
  • Section (mm²)
  • 1.5
  • Type of cable
  • H07 RN-F 3G
  • Number of motor(s)
  • Dual motor
  • Socket included
  • No
  • Voltage (V)
  • 220-240
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 2000
  • Power output P2 (W)
  • 1400
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 16
  • IP rating
  • IP68
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Current
  • Single-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Smart
  • Length (m)
  • 2,5
  • Section (mm²)
  • 1.5
  • Type of cable
  • H07 RN-F 3G
  • Number of motor(s)
  • Dual motor
  • Socket included
  • No
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 3500
  • Power output P2 (W)
  • 2800
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 12
  • IP rating
  • IP68
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Classic
  • Length (m)
  • 2,5
  • Section (mm²)
  • 2.5
  • Type of cable
  • H07 RN-F 5G
  • Number of motor(s)
  • Dual motor
  • Socket included
  • No
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 3500
  • Power output P2 (W)
  • 2800
  • Revolution per minute (RPM)
  • 2800
  • Maximum current (A)
  • 12
  • IP rating
  • IP68
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 4
  • Number of pumps
  • 2
  • Type of control box
  • Smart
  • Length (m)
  • 2,5
  • Section (mm²)
  • 2.5
  • Type of cable
  • H07 RN-F 5G

Hydraulic

  • Max. Head. (m)
  • Max. flow rate. (m³/h)
  • Number of inlets
  • External inlet diameter (mm)
  • Discharge diameter ext. (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Free passage (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Type of impeller
  • Type of activation
  • Max. Head. (m)
  • Max. Head. (m)
  • Max. flow rate. (m³/h)
  • Max. flow rate. (m³/h)
  • Number of inlets
  • Number of inlets
  • External inlet diameter (mm)
  • External inlet diameter (mm)
  • Discharge diameter ext. (mm)
  • Discharge diameter ext. (mm)
  • Ext. ventilation diameter (mm)
  • Ext. ventilation diameter (mm)
  • Total volume (L)
  • Total volume (L)
  • Useable volume (L)
  • Useable volume (L)
  • ON Level (mm)
  • ON Level (mm)
  • OFF level (mm)
  • OFF level (mm)
  • Alarm level (mm)
  • Alarm level (mm)
  • Free passage (mm)
  • Free passage (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Type of impeller
  • Type of impeller
  • Type of activation
  • Type of activation
  • Max. Head. (m)
  • 13.5
  • Max. flow rate. (m³/h)
  • 40
  • Number of inlets
  • 5
  • External inlet diameter (mm)
  • 40, 50, 110, 125, 100
  • Discharge diameter ext. (mm)
  • 90/110
  • Ext. ventilation diameter (mm)
  • 75
  • Total volume (L)
  • 120
  • Useable volume (L)
  • 26
  • ON Level (mm)
  • 165
  • OFF level (mm)
  • 95
  • Alarm level (mm)
  • 235
  • Free passage (mm)
  • 50
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 70 °C
  • Type of impeller
  • vortex
  • Type of activation
  • Pneumatic
  • Max. Head. (m)
  • 13.5
  • Max. flow rate. (m³/h)
  • 40
  • Number of inlets
  • 5
  • External inlet diameter (mm)
  • 125, 50, 40, 100, 110
  • Discharge diameter ext. (mm)
  • 90/110
  • Ext. ventilation diameter (mm)
  • 75
  • Total volume (L)
  • 120
  • Useable volume (L)
  • 26
  • ON Level (mm)
  • 165
  • OFF level (mm)
  • 95
  • Alarm level (mm)
  • 235
  • Free passage (mm)
  • 50
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 70 °C
  • Type of impeller
  • vortex
  • Type of activation
  • Pneumatic
  • Max. Head. (m)
  • 16
  • Max. flow rate. (m³/h)
  • 55
  • Number of inlets
  • 5
  • External inlet diameter (mm)
  • 110, 125, 50, 100, 40
  • Discharge diameter ext. (mm)
  • 90/110
  • Ext. ventilation diameter (mm)
  • 75
  • Total volume (L)
  • 120
  • Useable volume (L)
  • 26
  • ON Level (mm)
  • 165
  • OFF level (mm)
  • 95
  • Alarm level (mm)
  • 235
  • Free passage (mm)
  • -
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 70 °C
  • Type of impeller
  • vortex
  • Type of activation
  • Pneumatic
  • Max. Head. (m)
  • 16
  • Max. flow rate. (m³/h)
  • 55
  • Number of inlets
  • 5
  • External inlet diameter (mm)
  • 40, 110, 100, 50, 125
  • Discharge diameter ext. (mm)
  • 90/110
  • Ext. ventilation diameter (mm)
  • 75
  • Total volume (L)
  • 120
  • Useable volume (L)
  • 26
  • ON Level (mm)
  • 165
  • OFF level (mm)
  • 95
  • Alarm level (mm)
  • 235
  • Free passage (mm)
  • 50
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 70 °C
  • Type of impeller
  • vortex
  • Type of activation
  • Pneumatic

Logistics

  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • 101
  • Gross weight (kg)
  • 101
  • Gross weight (kg)
  • 102
  • Gross weight (kg)
  • 102

General description

  • EAN code
  • EAN code
  • EAN code
  • EAN code
  • 3308815063140
  • EAN code
  • 3308815076171
  • EAN code
  • 3308815074689
  • EAN code
  • 3308815076188
Products

Related products

FAQs

Frequently asked questions?

  • The Sanicubic 2 VX is a heavy-duty duplex wastewater lifting station featuring two 2000 watt vortex pumps. It is designed for residential, commercial, and industrial applications requiring reliable wastewater removal from multiple fixtures.

  • The unit is designed to pump both black water and grey water from toilets, sinks, showers, bathtubs, washing machines, dishwashers, and other sanitary fixtures.

  • Yes. It is specifically designed for demanding environments such as offices, warehouses, apartment buildings, schools, restaurants, and other high-usage facilities where reliable wastewater management is essential.

  • The Sanicubic 2 VX uses vortex impeller technology rather than a grinder system. The vortex design allows it to handle large solids up to 50 mm in diameter and significantly reduces the risk of clogging.

  • The two pumps operate alternately to balance wear and extend service life. During peak demand, both pumps can run simultaneously. If one pump stops working, the other can continue operating until maintenance is completed.

  • Yes. The unit features dual-access service panels and accessible internal components, making inspection, maintenance, and servicing quicker and more convenient.

  • The Sanicubic 2 VX is a heavy-duty duplex wastewater lifting station featuring two 2000 watt vortex pumps. It is designed for residential, commercial, and industrial applications requiring reliable wastewater removal from multiple fixtures.

  • The Sanicubic 2 VX uses vortex impeller technology rather than a grinder system. The vortex design allows it to handle large solids up to 50 mm in diameter and significantly reduces the risk of clogging.

  • The unit is designed to pump both black water and grey water from toilets, sinks, showers, bathtubs, washing machines, dishwashers, and other sanitary fixtures.

  • The two pumps operate alternately to balance wear and extend service life. During peak demand, both pumps can run simultaneously. If one pump stops working, the other can continue operating until maintenance is completed.

  • Yes. It is specifically designed for demanding environments such as offices, warehouses, apartment buildings, schools, restaurants, and other high-usage facilities where reliable wastewater management is essential.

  • Yes. The unit features dual-access service panels and accessible internal components, making inspection, maintenance, and servicing quicker and more convenient.

Quality

Buy with confidence

  • Experts Since 1958

    Creator of the Sanibroyeur macerating toilet.

  • Tailored Support

    Our team of experts is at your service.

  • Performance and Reliability

    Technologies and materials that ensure efficiency and longevity

  • Technical support

    More than 100 certified installers and repair technicians

  • Made in France

    Many products have received the Made in France label