Surface Pumps

Result (13)
  • Max. flow rate (m³/h)

Result (13)
  • New
    Badge flag
    Ambient image of a SaniMHP 9-5, horizontal multistage centrifugal pump for clear and rainwater, for water supply

    SaniMHP 9-50

    The SaniMHP 9-50 is a multi-stage, self-priming and quiet pump, offering a flow rate of 8.7 m³/h and a head of 50 m. Efficient and reliable, it guarantees a suction depth of up to 8 m.

  • New
    Badge flag
    Ambient image of a SaniMHP 6-5, horizontal multistage centrifugal pump for clear and rainwater, for water supply

    SaniMHP 6-50

    Horizontal, self-priming multistage pump for clear water: watering, pumping from tanks/pools, supplying decorative fountains. Flow rate 5.4 m³/h, head 52 m.

  • New
    Badge flag
    Ambient image of a SaniMHP 4-5, horizontal multistage centrifugal pump for clear and rainwater, for water supply

    SaniMHP 4-50

    The SaniMHP 4-50 is a quiet, self-priming, horizontal multistage surface pump, ideal for irrigation and pumping clear water.

  • New
    Badge flag
    Ambient image of a SaniMHP 4-4 PC3, horizontal multistage centrifugal pump with pressure control for clear and rainwater

    SaniMHP 4-40 PC3

    The SaniMHP 4-40 PC3 comprises the SaniMHP 4-40 multistage pump with the PC3 pressure control unit. It is suitable for a wide range of applications involving clear water.

  • New
    Badge flag
    Ambient image of a SaniMHP 4-4 PC2, horizontal multistage centrifugal pump with pressure control for clear and rainwater

    SaniMHP 4-40 PC2

    SaniMHP 4-40 pump with PC2 pressure control, ideal for watering, pumping and domestic use. Automatic activation, quiet operation.

  • New
    Badge flag
    Ambient image of the Sanijet SJ 4-5, surface jet pump for clear and rainwater, for irrigation

    Sanijet 4-50

    The Sanijet 4-50 is a surface pump designed to pump water from tanks, shallow wells, swimming pools and ponds, amongst other things, but also for watering the garden, for example from a rainwater collection tank.

  • New
    Badge flag
    Ambient image of a Sanijet 4-5 PC2, surface jet pump with pressure control for clear and rainwater, for water supply

    Sanijet 4-50 PC2

    Sanijet 4-50 surface pump with Presscontrol PC2, suitable for domestic water supply, watering, pumping and raw water supply (excluding aggressive or abrasive substances).

  • New
    Badge flag
    Ambient image of a Sanijet 4-5 PC3, surface jet pump with pressure control for clear and rainwater, for water supply

    Sanijet 4-50 PC3

    The Sanijet 4-50 surface pump with Presscontrol PC3 is designed for watering, pumping, domestic water supply and raw water supply. It switches on when a tap is turned on, and the pressure is adjustable.

  • New
    Badge flag
    Ambient image of a Sanijet 5-55, surface jet pump for clean and rainwater, for irrigation

    Sanijet 5-55

    The Sanijet 5-55 surface pump is a multistage jet pump ideal for watering, draining swimming pools and pumping clear water. High-performance and quiet.

  • New
    Badge flag
    Ambient image of a Sanijet 5-55 PC3, surface jet pump with pressure control for clear and rainwater, for water supply

    Sanijet 5-55 PC3

    The Sanijet 5-55 multistage pump, when used in conjunction with the Presscontrol PC3, is ideal for irrigation, pumping and supplying clean water. It switches on when a tap is turned on, and the pressure is adjustable.

  • New
    Badge flag
    Ambient image of a SaniMHP 4-4, horizontal multistage centrifugal pump for clean and rainwater, for water supply

    SaniMHP 4-40

    The SaniMHP 4-40 is a horizontal multistage surface pump designed for use in clear water.

  • New
    Badge flag
    Ambient image of a SaniMHP 4-5 PC3, horizontal multistage centrifugal pump with pressure control for clear and rainwater

    SaniMHP 4-50 PC3

    SaniMHP 4-50 pump with PC3 pressure control. Self-priming pump with pressure regulation. Versatile and high-performance.

FAQs

Frequently asked questions?

  • A jet pump is a surface-mounted pump that uses suction and pressure to draw water from wells, tanks, or other water sources.

  • Easy access for maintenance Lower installation cost Suitable for shallow and moderate-depth wells Reliable and durable operation

  • Priming involves filling the pump and suction line with water before startup to remove air and enable proper operation.

  • A multi-impeller pump contains two or more impellers mounted on the same shaft to generate higher pressure than a single-impeller pump.

  • Water passes through a series of impellers. Each impeller increases the pressure before the water moves to the next stage, resulting in greater overall pressure.

  • Jet pumps are commonly used in: Residential water supply systems Agriculture and irrigation Water transfer applications Rural properties with wells

  • Common causes include: Air leaks in suction piping Faulty non-return valve Low water level Leaking fittings Damaged seals

  • It is recommended to inspect the pump annually and regularly check seals, pressure switches, and suction piping.

  • High pressure generation Improved energy efficiency Smooth operation Compact design Reliable performance

  • Yes. They are often more energy-efficient for high-pressure applications than oversized single-stage pumps.

  • A jet pump is a surface-mounted pump that uses suction and pressure to draw water from wells, tanks, or other water sources.

  • Jet pumps are commonly used in: Residential water supply systems Agriculture and irrigation Water transfer applications Rural properties with wells

  • Easy access for maintenance Lower installation cost Suitable for shallow and moderate-depth wells Reliable and durable operation

  • Common causes include: Air leaks in suction piping Faulty non-return valve Low water level Leaking fittings Damaged seals

  • Priming involves filling the pump and suction line with water before startup to remove air and enable proper operation.

  • It is recommended to inspect the pump annually and regularly check seals, pressure switches, and suction piping.

  • A multi-impeller pump contains two or more impellers mounted on the same shaft to generate higher pressure than a single-impeller pump.

  • High pressure generation Improved energy efficiency Smooth operation Compact design Reliable performance

  • Water passes through a series of impellers. Each impeller increases the pressure before the water moves to the next stage, resulting in greater overall pressure.

  • Yes. They are often more energy-efficient for high-pressure applications than oversized single-stage pumps.

Quality

Buy with confidence

  • Experts Since 1958

    Creator of the Sanibroyeur macerating toilet.

  • Tailored Support

    Our team of experts is at your service.

  • Performance and Reliability

    Technologies and materials that ensure efficiency and longevity

  • Technical support

    More than 100 certified installers and repair technicians

  • Made in France

    Many products have received the Made in France label